Features
- 14mm LED display
- Up to 1600 convertion/sec
- Calibration via keys and by PC/PLC through interfaces
- Electronic calibration (eCAL) without test weights
- Span calibration (sCAL) of non-empty tanks.
System integration
- RS-232C serial port
- RS-485 serial port
- Modbus RTU
- Analog selectable as 0-20mA, 4-20mA, 0-5 VDC and 10 VDC
- Parallel I/O port as 4 x Inputs and 6 x Outputs
Linearity | % 0.0015 FS |
Temperature coefficient | 2 ppm/°C |
Display | 6 digits, 7 segments, red, 14 mm high |
Status annunciators | Gross, net, motion, centre of zero, units (kg, g, t, lb, klb, N, kN) |
Keyboard | 5-key (function, GN, tare/clear, zero, print) |
Key lock | Keys can be locked against unauthorized access |
Tiype (A/D Converter) | 24 bit Delta – Sigma ADC |
Conversion rate(A/D Converter) | Up to 1600 conversions per second |
Minimum input sensitivity (A/D Converter) | 0.1 μV per interval |
Analogue input range (A/D Converter) | 0 mV to + 18 mV (unipolar) ; -18mV to +18mV (bipolar) |
Resolution (A/D Converter) | Internal up to 16.000.000; display up to 999.999 d |
Type (D/A Converter) | 16 bit D/A converter |
Max. cable length (D/A Converter) | 300 meter |
Max. load resistance (D/A Converter) | 500 Ω |
Calibration | Standard: By etalon weights via keys or serial port via IndFace1x software |
eCal: Electronic calibration without etalon weights | |
sCal: Span calibration of non-emptied tanks. | |
Digital filter | 10 step adjustable adaptive digital filter |
Weighing functions | Tare, zero ing, auto zero tracking, motion detection, auto-zero at power-up |
Other functions | Label number, gross, tare indication |
Digital outputs | 6 set points with relay contact output. |
Digital inputs | 4 opto-isolated inp uts are programmable for zeroing, tare, clear, hold, peak, print etc. |
RS-232C | 1200 to 115200 baud, programmable |
Continuous, Printer, BSI (Baykon Serial Interface) protocol | |
RS-485 | 1200 to 115200 baud, 8 none 1, 7 even 1, 7 odd 1, 8 even 1 or 8 odd 1, Up to 31 units on the bus1200 to 115200 baud, 8 none 1, 7 even 1, 7 odd 1, 8 even 1 or 8 odd 1, Up to 31 units on the bus |
Modbus RTU | 1200 to 115200 baud, 8 none 1, 8 even 1 or 8 odd 1, up to 31 units on the RS-485 bus |
Analogue | Programmable to 4 – 20 mA, 0 – 20 mA, 0 – 5 VDC or 0 – 10 VDC |
Excitation | 5 VDC, max. 100 mA |
Number of load cells | Up to 6 load cells 350 Ω or 18 load cells 1100 Ω in parallel |
Connection | 4 or 6 wire technique. Cable length 274 m/mm² for 6 wire connection |
Operation temperature | -15°C to +55°C; 85% RH max, non-condensing. |
Enclosure | Polycarbonate, mounting in standard DIN rails, IP20 |
89,7 mm x 107,6 mm x 62,2 mmPolycarbonate, mounting in standard DIN rails, IP20, 89,7 mm x 107,6 mm x 62,2 mm | |
Power Requirement | 12 – 28 VDC, Max. 0.2 A |
Ulasan