Features
- 16.000.000 internal resolution
- Big LED display
- Programmable via PC
- RS-232C serial interface
- Ergonomic design with small size
BX10MB has additionaly;
- RS485 serial interface
- 2 pcs programmable digital In/Out
Powerful calibration
- Calibration with test weight
- eCal Electronic calibration
- Calibration via serial interface
- Span calibration under load
Accuracy class | OIML class III |
EU type approval | 10.000 division |
Linearity | % 0.0015 FS |
Temperature coefficient | ≤ 2 ppm/°C |
Display | 6 digits, 7 segments, red, 13,5 mm high |
Status annunciators | Gross, net, motion, centre of zero, unit |
Keyboard | 5-keys (function, GN, tare/clear, zero, print) |
Key lock | Keys can be locked against unauthorized access |
Type | 24 bit Delta-Sigma ratiometric ADC |
Conversion rate | Up to 1600 measurements per second |
Minimum input sensitivity | 0.4 μV/d (Approved); 0.1 μV/d (Non approved) |
Analogue input range | 0 mV to -18 mV (unipolar); -18 mV to +18 mV (bipolar) |
Resolution | Internal up to 16.000.000; up to 10 000 increment (Approved); up to 999 999 increment (Non approved) |
Calibration | eCal: Electronic calibration without etalon weights |
sCal: Span calibration of non-emptied tanks | |
Digital filter | 10 step adjustable adaptive digital filter |
Weighing functions | Tare, zeroing, auto zero tracking, motion detection, auto-zero at power-up. |
Other functions | Label number, gross, tare indication. |
I / O port | 2 ports can be programmed as digital input or digital output, non-isolated |
RS-232C seri port | 1200 to 115200 baud, programmable |
Continuous, Printer, BSI (Baykon Serial Interface) protocol | |
RS-485 seri port | 1200 to 115200 baud, programmable, 8 none 1, 7 even 1, 7 odd 1, 8 even 1 or 8 odd 1, up to 31 units on the bus |
Modbus RTU | 1200 to 115200 baud, 8 none 1, 8 even 1 or 8 odd 1, up to 31 units on the RS-485 bus |
Excitation | 5 VDC, max. 300 mA |
Number of load cells | Up to 8 load cells 350 Ω or up to 24 load cells 1100 Ω (min 43 ohm– max 1200 ohm) |
Connection | 4 or 6 wire technique. Cable length 1000 m/mm² for 6 wire connection |
Operation temperature | -15°C to +55°C |
Enclosure | Panel type, aluminum body, plastic front panel, stainless steel rear panel |
48mm x 96mm panel size; 100mm depth | |
Power requirement | 12 – 28 VDC, max. 300 mA |
BX10 variants | |
BX10 | RS-232C, 2 pcs progmmable digital input and output. |
BX10 MB | Modbus RTU on RS–485 or RS-232C, 2 pcs programmable digital input and output. |
Ulasan